VOLUME and FLOWRATE OF WATER AND LIQUIDS

Quantity 

Volume flow - volume of liquid passing through the meter divided by the time unit.
Mass flow - mass of liquid passing through the meter divided by the time unit.
Delivered mass or volume.

Unit - m3/h, l/h, l/s, l/min (volume flow), t/h, kg/h, kg/s, kg/min (mass flow).

Tasks of the laboratory

The main task of the Laboratory is realisation of volume flow, mass flow, delivered mass and volume units for liquids, calibration of flow meters and volume meter.

Available metrological services

Calibration of standards of flowrate and volume flow of water and liquids (range: from 0.02 m3/h to 270 m3/h; expanded uncertainty (k=2) is 0.03 %). calibration and verification of cold water meters, hot water meters and volumetric parts of heat meters (range: from 0.02 m3/h to 270 m3/h; expanded uncertainty is 0.2 %). Calibration and verification of flow meters other than water. calibration and verification of massflow meters (range: from 0.02 m3/h to 270 m3/h; expanded uncertainty is 0.1 %). Calibration of test assemblies for water meters (range: from 0.01 m3/h to 1000 m3/h; expanded uncertainty is 0.03 %). Calibration of Volumetric Tanks (range: from 2 dm3 to 5 000 000 dm3; expanded uncertainty is 0.2 %).

Methods of measurement:

  • verification of secondary standards is performed in an accordance with the national regulation, pattern testing og water meters is performed in an accordance with the Act of metrology of Slovak republic and in an accordance with the ISO standards. verification is performed direct with comparison the SMU standards.


Instuments in use


For verification of secondary standards of 1. and 2. orders and for testing for type approval of water meters is used the

National Standard of Flowrate of cold and hot water
. It is a gravimetric standard device with switching flappervalve, with a range of measurement up to 270 m3/h within a temperature range up to 85°C. water meters pattern testing is performed using a reference standards - volume flow meter with a piston and a standard electromagnetic inductance flow meter.
Pattern testing of flowmeters for technical liquid as well as verification of secondary standards of technical liquids flowrate is performed using a calibrated measuring container and calibrated balance.

Pattern testing and verification of meters of medium and large volume of liquid is performed using calibrated measuring containers and geometrical methods.



GAS VOLUME AND FLOWRATE LABORATORY

Quantity

Volume flow - volume of liquid passing through the meter divided by the time unit.
Mass flow - mass of liquid passing through the meter divided by the time unit.
Delivered mass or volume.

Unit - m3/h, l/h, l/min (volume flow); kg/h, kg/min (mass flow).

Tasks of the laboratory

The main task of the Laboratory is realisation of volume flow, mass flow, delivered mass and volume units for gas, calibration of flow meters and volume meters.

International comparisons

The SMU flow standards are regulary compared to secondary standards of authorized bodies in Germany, Switzerland and in the other western countries. Transfer standards - a set of critical nozzles is traceable to the primary standard of the PTB, Braunschweig, Germany.

Available metrological services

Calibration of gas flow volume and flowrate standards of 1. and 2. orders (with a measurement range from 0.001 m3/h to 400 m3/h). Calibration and verification of gasmeters working with volumetric principle, of gas flowrmeters (with a mearument range from 0.001 m3/h to 400 m3/h). Calibration and verification of gasmeters by nozles sonical (with a measurement range from 0.01 m3/h to 270 m3/h). Expanded uncertainty (k=2) for these given services is 0.2 %.
Calibration and verification of conversion devices for gas (with a measurement range from 0.1 MPa to 6 MPa and (-20)°C to 60°C, expanded uncertainty (k=2) is 0.5 %.

Methods of measurement: 

  • the calibration of standards and verification of ordinary instruments is performed in accordance with the National legislative and the OIML reccomendations. The verification is performed at standard devices of the SMU by a method of direct traceability or by reference standards.

Instuments in use
 

For a verification of standards of 1. and 2. orders and for pattern testing the primary standards are used as follows: equivalent volume of discharged liquid with a measurement range from (0.01 up to 3) m3/h and with a total uncertainty of 0.1 % of RDG Bell volume meter - with a measurement range from (1 up to 65) m3/h; a standard drum-type gas meter with a range up to 16 m3/h (a total uncertainty is 0.15 % of RDG); for pattern testing of gas meters rotary gas meters with a range of measurement up to 40 m3/h and 400 m3/h, resp. sets of critical nozzles are used; set of nozzles (0.06 to 63) m3/h - transfer standard, expanded uncertainty is 0.21% (kU=2).